Labs
Our research infrastructure is operated on a shared facility basis and is therefore accessible across departments (subject to certain conditions and terms of use).
On this page, you will find an overview of our laboratory facilities. If you are interested in using a facility, please contact the relevant contact persons or operators listed.
Behavioural Lab (Health Psychology)
The Behavioural Lab can be used by members of the faculty to study food choice under realistic conditions. To this end, the Lab is equipped with a buffet featuring realistic food replicas.
The Lab is provided by the Health Psychology research group.
Further information
- Buffet with realistic food replicas (“fake food”), serving bowls and cutlery, plates and bowls
- Computer workplace
- Scales (Omron BF511 Body Composition Monitor) and height rod
- Partition walls
Liebiggasse 5
Basement
1010 Vienna
Biochemical Lab
The Biochemical Laboratory (BCL) of the Clinical Adult Psychology research group, headed by Univ.-Prof. Dr. Urs Markus Nater and Dipl.-Psych. Dr Nadine Skoluda, is a research-oriented laboratory specialising in stress research. Consequently, the BCL primarily utilises biochemical methods for the quantitative determination of stress-associated biomarkers from saliva, blood and hair, including endocrine markers, markers of the autonomic nervous system and immune markers.
Further information
- Liebherr GKv 4310 and FKUv 1610 fridge
- Liebherr LGPv 1420 MediLine freezer (-20°C)
- Panasonic MDF U731M freezer (-30°C)
- Panasonic MDF DU702VX-PE ultra-low temperature freezer (-80°C)
- Kern 572-32 precision balance
- Ohaus Adventurer AX224 analytical balance
- Hermle Z 207 A small centrifuge
- Hermle Z 216 MK refrigerated microlitre centrifuge
- Hermle Z 446 K benchtop refrigerated centrifuge
- Labogene Mars 1800 sterile workbench
- Stuart sample concentrator evaporator – block heaters with N2 gas supply
- Phoenix EC-30 pH meter
- Panasonic MCO-170AICD CO₂ incubator
- Adrona water treatment system for ultrapure water
- Grant JB Nova water bath
- Panasonic MLS-3781L autoclave
- Tuttnauer TIVA 500C LAB laboratory washer
- Tecan Hydrospeed microplate washer (96-well format)
- Biotek Synergy HTX multi-mode microplate reader (absorbance, luminescence)
- Tecan Sunrise microplate photometer (absorbance)
- Ella Automated Immunoassay System (R&D Systems, Bio-Techne)
At the BCL, biochemical methods are predominantly used for the quantitative determination of stress-associated biomarkers. These biomarkers are analysed in the following biological sample types:
- Blood (serum, plasma)
- Saliva: There are various standardised methods for collecting saliva samples. The choice of the appropriate method depends, amongst other things, on the analytes of interest and the sample being analysed. Established methods include:
- the use of an absorbent material and sample collection tube (e.g. Salivette)
- the passive drool method using a sample collection tube and straw (e.g. SaliCap)
- Hair: Hair offers the possibility of retrospectively measuring cumulative hormone releases, e.g. of cortisol.
The stress-associated biomarkers investigated include the following:
- endocrine markers: hormones, such as cortisol (from saliva, blood or hair), adrenocorticotropic hormone (from blood), testosterone (from saliva), dehydroepiandrosterone, DHEA (saliva)
- Markers of the autonomic nervous system: catecholamines (from blood), alpha-amylase (from saliva)
- Markers of the immune system: cytokines (from blood and saliva), immunoglobulins (from blood and saliva), lymphocyte subpopulations (from blood)
The following methods are used at the BCL:
- Immunoassays: These are methods for quantifying analytes using an antigen-antibody reaction. The following immunoassays are used at the BCL:
- Enzyme-linked immunoassays (ELISA)
- Luminescence immunoassay (LIA)
- Ella Automated Immunoassay System (Simple Plex Cartidges)
- Enzymatic photometric test: This test is used to optically determine the activity of enzymes, such as alpha-amylase.
Vienna BioCenter 2
1st floor
1030 Vienna
Brain Stimulation Lab
The Brain Stimulation Lab has two different systems for conducting studies using transcranial stimulation. These enable the activity of specific brain regions to be modulated for short periods in order to investigate the role of these regions in cognition and behaviour.
The transcranial magnetic stimulation (TMS) system comprises, in addition to the stimulation device itself, a system for the stereotactic localisation of the brain structures of interest, and several figure-of-eight double coils, one of which is self-cooling. The transcranial direct current stimulation (tDCS) system comprises a direct current stimulator, as well as various application aids for the secure attachment of the electrodes.
Further information
TMS system
- 1 Magstim Super Rapid² stimulator
- 2 figure-of-eight double coils (Double 70mm Alpha Coil)
- 1 self-cooling double coil (Double 70mm Air Film Coil)
- 1 mount for the stimulation coils (Magstim Articulated Coil Stand)
- 1 stereotactic localisation system (Brainsight TMS Navigation)
- NDI Vicra: optical tracking system with mobile camera tripod
- Quad-core i7, 27″ iMac
- Tracking aids (trackers for participants, pointing rod, coils and calibration block)
- 1 motor-evoked potential (MEP) recording device, two channels
- 1 specialised chair with chin rest for participant comfort during longer experiments
TDCS system
- 1 direct current stimulator
Focused ultrasound stimulation
- 1 BrainSonix BX Pulsar 1002 transducer
Liebbiggasse 5
1010 Vienna
Left staircase, basement labs
As you exit the lift, go through the door on the left, follow the corridor and go through the door at the end of the corridor. The Brain Stimulation Lab is located behind the door opposite.
Cognition Research Lab
The Cognition Research Lab specialises in research methods used in modern cognitive and perceptual psychology.
In addition to behavioural experiments conducted on computers, which involve measuring reaction times and evaluating presented stimuli, various psychophysiological measurements are also carried out.
Further information
Eye tracking (eye movement tracking)
- 3 stationary eye trackers: 2 EyeLink 1000, desktop mount (SR Research), 1 EyeLink 1000 Plus, desktop mount (SR Research)
- Eye-tracking glasses: 1 pair of Tobii Pro Glasses 3 Wireless 50, 1 pair of Pupil Labs Neon eye-tracking glasses, several pairs of Pupil Labs Core open-source eye-tracking glasses
Measurement of EEG (electroencephalogram), EMG (electromyogram), EOG (electrooculogram) and EDA (electrodermal activity)
- 1 stationary amplifier: Refa8 32-channel amplifier (TMSi)
- 8 portable recording devices: Mobi8-BP 12-channel amplifier (TMSi)
- 1 USB 16-channel biosignal amplifier: g.USBamp (g.tec) (shared with the SCAN unit)
- 1 fMRI-compatible full-band DC–EEG system: eldith NeuroPrax MR (neuroConn) (shared with the SCAN unit)
- 1 128-channel Biosemi EEG system
- Active electrodes: actiCap (Brain Products)
fNIRS (functional near-infrared spectroscopy)
- NIRx NIRSport system, fully portable, with 8 emitters and 8 detectors
- 2 NIRx NIRSport2 systems
Behavioural measurements
- 7 behavioural laboratories (equipped for parallel testing of 2 to 5 people)
- over 20 PCs
- Button boxes for recording reaction times in the millisecond range (Cedrus RB-740, PST Serial Response Box)
- 1 VoiceKey (for recording reaction times via acoustic signals)
- 1 i1Pro colourimeter (X-Rite)
- Eye-tracking can be used to measure the eye movements of test subjects, for example to analyse perceptual processes, attention control, etc.
- Electrophysiological methods allow, amongst other things, the measurement of brain activity (EEG) and emotional responses (EDA, facial EMG).
- fNIRS uses light-emitting diodes placed on the scalp to transmit light through the skull. This light is reflected by the oxygen in the blood; based on local blood flow, it is possible to obtain an accurate measure of the relative activation of the cerebral cortex.
Faculty of Psychology
Liebiggasse 5
1010 Vienna
- Staircase 1:
Basement rooms: TR K1 to TR K5, one data analysis room
2nd floor: TR II-1 - Staircase 2:
Basement rooms: TR K6 to TR K7, EEG basement laboratory
EEG Labs
The Faculty of Psychology operates several state-of-the-art electroencephalography (EEG) Lab.
These EEG Lab are provided by various research groups (the SCAN Unit, the Cognitive Psychology Group, the Developmental Psychology Group and EVAlab).
Further information
EEG systems and amplifiers
- 2 NEUROPRAX 64-channel DC EEG amplifiers (model number 0022, neuroConn)
- 1 eldith NEUROPRAX MR 64-channel DC EEG amplifier (model number 0011, neuroConn)
- 1 g.USBamp, 16-channel bipolar DC EEG amplifier with 4 separate grounds (g.tec)
- 1 128-channel Biosemi EEG system
Additional equipment
- EEG caps with Ag/AgCl electrodes (EASYCAP)
- EEG electrode impedance meter (Zickler)
- SIGGI signal generator (EASYCAP)
- E-Prime 2.0 software for computer-based experimental design, the presentation of sensory stimuli and the recording of behavioural data
- Eyelink 1000 eye tracker (SR Research)
- The SCAN Unit is equipped with three 64-channel DC EEG systems (from neuroConn, Germany). A variety of electrophysiological signals can be measured, such as the electroencephalogram (EEG), event-related potentials (ERPs), the electromyogram (EMG), the electrooculogram (EOG) and the electrocardiogram (ECG). One of the amplifiers is suitable for use within a magnetic resonance imaging (MRI) scanner and can also be used ‘online’ in combination with transcranial magnetic stimulation (TMS). Additional equipment includes a bipolar 16-channel DC amplifier for psychophysiological signals. All laboratories feature soundproof and electrically isolated recording chambers (from Desone, Germany).
- Location: Liebiggasse 5
- Contact: SCAN-Unit
- The Cognitive Psychology Research Group has an active, high-density 128-channel EEG system from Biosemi. In addition to the EEG, this laboratory can simultaneously record eye-tracking and pupillometry (SR-Research Eyelink 1000), and auditory stimuli can be presented with minimal artefacts using the Eartone headphone system
- Contact: Mag. Dr. Ulrich Pomper
- In addition to these laboratories, which are primarily used for research involving adults, the Wiener Kinderstudien Lab is the provider of an EEG facility for psychological studies with children.
- Contact: kinderstudien(at)univie.ac.at
- Furthermore, the EVA Lab is the provider of a “Mobile Lab”, which comprises a portable EEG system with active electrodes for use in the field
EMA Lab
The Ecological Momentary Assessment (EMA) Lab supports researchers through equipment lending.
Mobile phones with the movisensXS software pre-installed, as well as other equipment (chest straps, electrodes, sensors and wristbands), can be borrowed from the EMA Lab. Tablets are also available to enable data collection in digital and mobile formats.
Further information
- Nokia 5.3 smartphones, including the movisensXS app
- Samsung A05s smartphones, including the movisensXS app
- Galaxy Tab A8 X200 32GB tablets
- Sensors:
- EcgMove 4 (ECG and activity sensor)
- EdaMove 4 (EDA and activity sensor)
- Move 4 (activity sensor)
- OURA 4 (activity, HRV, cycle)
- Chest and hip straps as well as wristbands in various sizes
- Charging cables
Applications, general enquiries, availability and collection: Dr Christina Ristl, emalab.psychologie(at)univie.ac.at
Please note that the relevant application and information sheet (PDF) must be consulted when carrying out projects using EMA Lab equipment. A written application is required to borrow EMA Lab equipment!
Department of Clinical and Health Psychology
Wächtergasse 1 (5th floor)
1010 Vienna
Mobile Labs
The EVAlab (Empirical Visual Aesthetics) has the resources for field-based neuroscientific and psychophysiological research into aesthetics and related phenomena. This includes both a portable 64-channel EEG system with active electrodes and mobile psychophysiological sensors (ECG, EMG, SCR, PPG). The latter complement the eight existing mobile amplifiers (Mobi8-BP 12-channel amplifiers). In addition, several functional near-infrared spectroscopy devices (NIRSport) are available, which can be used both in the laboratory and in the field. Furthermore, several pairs of mobile eye-tracking glasses are available.
Further information
- LiveAmp 64 wireless EEG amplifier (Brain Products)
- actiCAP slim active electrode system for EEG recordings (Brain Products)
- NIRSport portable fNIRS system with 8 emitters and 8 detectors (NIRx)
- 2 NIRSport2 fNIRS systems with 8 emitters and 8 detectors (NIRx)
- Consensys Bundle Development Kit including portable ECG, EMG, EDA and PPG sensors (Shimmer Sensing)
- 2 Core open-source eye-tracking glasses (Pupil Labs)
- Neon eye-tracking glasses (Pupil Labs)
- Tobii Pro Glasses 3 Wireless 50 (Tobii)
Faculty of Psychology
Liebiggasse 5
1010 Vienna
(basement)
MR Centre
The MR Centre is a research facility specialising in magnetic resonance imaging (MRI). At its heart is a 3-Tesla Siemens Skyra whole-body scanner, which can be used to carry out not only functional (fMRI) but also structural and spectroscopic measurements. As a “shared facility”, the MR Centre is available to all staff at the University of Vienna, as well as to external collaboration partners. The focus is on fMRI and research questions in the fields of social, cognitive, affective and clinical neuroscience.
Further information
At the heart of the MR Centre is a Siemens MAGNETOM Skyra 3 Tesla MR scanner, equipped with a state-of-the-art gradient system and a 32-channel head coil, which enable high-resolution structural and functional imaging. In addition, fMRI studies combining electroencephalography (EEG) and transcranial magnetic stimulation (TMS) can be carried out in collaboration with the EEG laboratories and the Brain Stimulation Lab.
- Siemens MAGNETOM Skyra 3 Tesla MRI scanner (internal dimensions: 163 cm × 70 cm)
- Siemens 32-channel head coil, 24-channel head coil, canine head coil (University of Vienna, RF Lab, K9 coil), knee coil, spinal coil
- PC workplace for stimulus presentation and real-time fMRI neurofeedback (Intel i9 8 × 3.66 GHz, 32 GB RAM)
- MR-compatible 32-inch screen for stimulus presentation (BOLDscreen 32 LCD for fMRI, Cambridge Research Systems)
- MR-compatible eye tracker (EyeLink 1000 Plus, SR Research)
- MR-compatible physiology and skin conductance measurement system (BrainAmp ExG MR 16, Brain Products)
- MR-compatible headphone system (S14, Sensimetrics)
- MR-compatible response pad (4-Button Fibre Optic Response Pad, Current Designs)
The MR Centre was established as part of a collaborative infrastructure project and funded by the Federal Ministry of Science, Research and Economy (Interdisciplinary Translational Brain Research Cluster with High-Field MR Magnetic Resonance, Higher Education Space Structure Funding Initiative).
Vienna University Dental Clinic
Department of Radiology
Sensengasse 2a
1090 Vienna
- Manager: Ronald Sladky, Bakk. MSc PhD
- Support with MRI study design and planning
- Scanner hardware and software support
- Support with real-time fMRI neurofeedback studies
- Project management and planning
- MRI safety management
- User training
- Head: Prof. Claus Lamm
- Management and supervision
- Collaborative projects
- Public relations
Music and Health Lab
The Music and Health Lab is part of the Clinical Adult Psychology research group and is headed by Univ.-Prof. Dr. Urs Markus Nater. The Lab investigates the biopsychosocial foundations of the positive effects of music on the body and mind.
Observation Lab
Since 2022, the Outpatient Unit for Research, Teaching and Practice has had an observation laboratory equipped with Noldus technology, which can be operated from an adjoining room.
The observation room is suitable for both research and practical sessions where behavioural observation is the main focus. It is possible to record video of up to four people simultaneously and subsequently code and analyse the footage using the software.
Further information
- 1 round table and 4 chairs in the Obervation Lab
- 4 dome cameras (with zoom and pan functions)
- 1 table microphone
- 2 wireless lavalier microphones
- 1 intercom
- 1 workstation with Noldus Observer XT and Mediarecorder software in the adjoining room
If you are planning to conduct a study in the Observation Lab, please contact Lukas Kraiger well in advance. Please note that capacity is limited and that authorisation from the management of the Outpatient Unit for Research, Teaching and Practice is required before the study can begin. You should therefore allow sufficient lead time.
Outpatient Unit for Research, Teaching and Practice
Wächtergasse 1
1st floor, room 109
1010 Vienna
Social Science Lab
The Social Science Lab is designed primarily for computer-aided experiments.
It is equipped with 20 networked participant computers (including high-resolution monitors and over-ear headphones) separated by privacy partitions. The lab space can also be further partitioned using mobile walls. The lab space offers great flexibility for a variety of procedures beyond computerized studies, such as group interviews.
Further information
NIG, Neues Institutsgebäude
6th floor, rooms D609, D611, D613 and D615
Universitätsstraße 7
1010 Vienna
Study Room (Psychology of Ageing)
The Psychology of Ageing research room forms part of the Psychology of Ageing research group and is used to conduct studies and interviews. The room is equipped with two computer workplaces separated by a partition. The windows can be partially darkened.
Further information
- 2 workplaces with computers
Faculty of Psychology
3rd floor, Room 03.48
Liebiggasse 5
1010 Vienna
Wiener Kinderstudien Lab
The Wiener Kinderstudien Lab is part of the Developmental Psychology research group and conducts research into the early social-cognitive development of babies and children.
The Lab integrates various measurement methods, such as physiological measurements, behavioural observation and eye-tracking.
Further information
- NIRSport II model portable NIRS imaging system from NIRX with 8 emitters and 8 detectors
- BrainAmp DC 64-channel system for recording EEG and ECG from Brain Products; active electrodes: actiCAP from Brain Products
- 2 VideoSyncPro systems (each with 3 linked cameras) from Mangold
- Eye tracker: EyeLink 1000 Plus
- In functional near-infrared spectroscopy (fNIRS), infrared light is emitted into the head via optodes and recorded by sensors. Depending on the oxygen content of the blood, different wavelengths of light are absorbed, enabling conclusions to be drawn about neuronal activation in different areas of the brain.
- Electroencephalography (EEG) measures the brain’s electrical activity via electrodes placed on the surface of the head. Neural rhythms are thus recorded and plotted graphically.
- Electrocardiography (ECG) is used to measure the heart’s electrical activity.
- Eye-tracking records the eye movements of participants as well as pupil size. This makes it possible to investigate where people direct their visual attention.
- For behavioural observation, interactions between two people, for example, are filmed and later systematically coded and analysed.
You can find further information on the Wiener Kinderstudien Website.
Faculty of Psychology
Liebiggasse 5
Right-hand staircase, 1st floor
Rooms 01.36 to 38
1010 Vienna